Posted: Mon Mar 23, 2009 6:32 am Post subject: Cannot initialized connection. Please reconnect to ODB-II |
|
|
This is the second time only that I've tried doing this - the first time was a few years ago and it worked fine. Since then, I've had a new HD, re-installed all the software, etc, and got MaxQ working again.
It sees all the OBD2 data in flight, but when I try to clear a CEL, I just get "Cannot initialized connection. Please reconnect to ODB-II"
I don't have a GPS installed.
I did the log serial/debug, then selected 'get codes' and this is what appeared:
Ping for MQ25
Received 0 bytes:
Not MQ25
Checking for MQ
Received 31 bytes: 21 6b 61 3c 3c 21 6b 76 45 74 61 2e 2e 2e 2e 2e 31 30 31 30 30 32 31 31 37 37 21 6b 61 3c 3c
Found MQ-Multi
Checking for PWM
Received 46 bytes: 21 6b 61 3c 3c 21 32 6d 30 30 30 33 38 3a 37 34 34 30 38 30 35 37 30 37 37 3f 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 35 3d 3c 36
Checking for VPW
Received 46 bytes: 21 6b 61 3c 3c 21 32 6d 30 30 30 33 38 3b 3a 35 34 30 38 30 35 37 30 37 37 3f 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 35 3d 3c 3b
Checking for ISO 9141-2
Received 46 bytes: 21 6b 61 3c 3c 21 32 6d 30 30 30 33 39 35 35 3f 34 30 38 30 35 37 30 33 37 3f 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 35 39 3c 33
I'd love for this to work as I leant my snap-on scanner to someone who has now left our company and clearly doesn't want to give it back. Grrrrrr... |
|